HARDWARE


Eye-One Pro spectrophotometer
Calibration plate - contains the white reference tile used to calibrate the Eye-One before use.
Scanning ruler - used as a guide when measuring test targets in scanning mode.
Positioning target - used as a guide when measuring test targets in patch mode.
CRT monitor holder - uses a suction cup to attach the Eye-One to the screen.
Flat panel holder - has a counterweight to balance the Eye-One against the screen.
Ambient light head and dark calibration cap - used to measure ambient light.

The box also contains a USB cable, software CD, quick start guide, scanner target (for use if the scanner profiling upgrade is purchased), calibration certificate and registration card.

SPECIFICATIONS

General
Spectral analyser Holographic diffraction grating with diode array detector
Spectral range 380nm to 730nm in 10nm steps
Measurement aperture 4.5mm
Communications USB 1.1 (high power device)
Dimensions Length 151mm, width 66mm, height 67mm
Weight 185g
Reflectance
Measurement geometry 45°/0° ring illumination optics, DIN 5033
Light source Gas filled tungsten (type A)
Inter-instrument agreement Average DE*94 0.4, maximum DE*94 1.0
Short-term repeatability DE*94 <= 0.1 (D50, 2°)
Emission
Dynamic range 0.2 to 300 cd/m2
Short-term repeatability x,y +/- 0.002 (CRT 5000K, 80 cd/m2)